National Repository of Grey Literature 6 records found  Search took 0.00 seconds. 
Stabilized operation and short - circuit conditions within E.ON 110 kV power network supplied from Čebín 110kV switching station, during the period of 2011
Chrástek, Radim ; Janda, Petr (referee) ; Blažek, Vladimír (advisor)
The aim of this thesis is to project an operation of bridge connection in distribution network in Čebín’s nodal area. The main task is to check a fulfilment of voltage tolerance in distribution substations 110 kV, load transformer control (400/110 kV, 110/VN kV), distribution power line 110 kV control and short - circuit conditions control. Relevant calculations are performed by dispatching control system, which works with the actual parameters of all distribution network‘s 110 kV facilities. The theoretical part of this thesis is devoted to the way of the calculation of stabilized operation and the short-circuit conditions. In practical part, first we perform an analyse of stabilized operation and the short-circuit conditions of distribution network 110 kV in actual operation. Next step deals with bridge connection design and analysing its operation. The operation of bridge connection is verificated even in specific conditions (disturbance state, increased load). The next section evaluates the results of the calculations. First we deal with actual operations evaluation and proposed the bridge connection. In the next section we evaluate the operation of the bridge connection in the specific operating conditions. Finally, we evaluate the losses in the distribution network 110 kV. If the calculations of the stabilized operation or the short-circuit conditions of distribution network discovers that some of its elements are overloaded, we propose changes to ensure safe and reliable operation of the distribution network.
Load Flow Calculation of Chosen Part of E.ON 110kV Grid with Analysis of Reactive Power Flow
Skoupý, Martin ; Vaculík, Petr (referee) ; Toman, Petr (advisor)
Content of this bachelor thesis is theoretic introduction to the steady state of network and optimization of network operation from the viewpoint of reducing active power losses in the electric wiring. Furthermore, the work deals with analysis of the network traffic flow distribution of the active and reactive power and consequences of overflow of the reactive power from the medium voltage level to the high voltage level. The following part includes designing practical involvement of the area and carrying out calculations of its operation in terms of losses. Another chapter is proposition of measures to minimize the overflowing of reactive power in distribution system and its impact on reduction of operating losses in the network. In the conclusion the work summarizes results obtained and the final assessment of influence of reactive power for operation of the network.
Feeding power out of 110/22 kV Moravany u Brna substation
Chromík, Aleš ; Beneš, Jan (referee) ; Blažek, Vladimír (advisor)
The aim of this Master’s thesis is the design and reconstruction of the high voltage distribution network for the company E. ON with focus on calculation of the stabilized operation and on the planning of new cable taps from the transformer substation Moravany u Brna. The first part of the theoretical analysis of the work deals with the inclusion of the distribution network into the power system and with principles of development and construction of high voltage networks. The second part includes a general calculation of stabilized operation of the power distribution network and a familiarization with the program PAS Off - Line Bison 4.0. The practical part of the thesis is focused on the calculation of the stabilized operation at the current state of transformer substation Moravany u Brna using the PAS Off - Line Bizon 4.0 V programme. This part also contains the design of six new cable lines which are needed to strengthen the power distribution in the southern part of the city Brno. The closing part of this chapter constitutes of a outdoor and indoor cable line renovation. These cables are connected to the transformer substation Moravany u Brna and a calculation of stabilized operation is also included in this part.
Load Flow Calculation of Chosen Part of E.ON 110kV Grid with Analysis of Reactive Power Flow
Skoupý, Martin ; Vaculík, Petr (referee) ; Toman, Petr (advisor)
Content of this bachelor thesis is theoretic introduction to the steady state of network and optimization of network operation from the viewpoint of reducing active power losses in the electric wiring. Furthermore, the work deals with analysis of the network traffic flow distribution of the active and reactive power and consequences of overflow of the reactive power from the medium voltage level to the high voltage level. The following part includes designing practical involvement of the area and carrying out calculations of its operation in terms of losses. Another chapter is proposition of measures to minimize the overflowing of reactive power in distribution system and its impact on reduction of operating losses in the network. In the conclusion the work summarizes results obtained and the final assessment of influence of reactive power for operation of the network.
Feeding power out of 110/22 kV Moravany u Brna substation
Chromík, Aleš ; Beneš, Jan (referee) ; Blažek, Vladimír (advisor)
The aim of this Master’s thesis is the design and reconstruction of the high voltage distribution network for the company E. ON with focus on calculation of the stabilized operation and on the planning of new cable taps from the transformer substation Moravany u Brna. The first part of the theoretical analysis of the work deals with the inclusion of the distribution network into the power system and with principles of development and construction of high voltage networks. The second part includes a general calculation of stabilized operation of the power distribution network and a familiarization with the program PAS Off - Line Bison 4.0. The practical part of the thesis is focused on the calculation of the stabilized operation at the current state of transformer substation Moravany u Brna using the PAS Off - Line Bizon 4.0 V programme. This part also contains the design of six new cable lines which are needed to strengthen the power distribution in the southern part of the city Brno. The closing part of this chapter constitutes of a outdoor and indoor cable line renovation. These cables are connected to the transformer substation Moravany u Brna and a calculation of stabilized operation is also included in this part.
Stabilized operation and short - circuit conditions within E.ON 110 kV power network supplied from Čebín 110kV switching station, during the period of 2011
Chrástek, Radim ; Janda, Petr (referee) ; Blažek, Vladimír (advisor)
The aim of this thesis is to project an operation of bridge connection in distribution network in Čebín’s nodal area. The main task is to check a fulfilment of voltage tolerance in distribution substations 110 kV, load transformer control (400/110 kV, 110/VN kV), distribution power line 110 kV control and short - circuit conditions control. Relevant calculations are performed by dispatching control system, which works with the actual parameters of all distribution network‘s 110 kV facilities. The theoretical part of this thesis is devoted to the way of the calculation of stabilized operation and the short-circuit conditions. In practical part, first we perform an analyse of stabilized operation and the short-circuit conditions of distribution network 110 kV in actual operation. Next step deals with bridge connection design and analysing its operation. The operation of bridge connection is verificated even in specific conditions (disturbance state, increased load). The next section evaluates the results of the calculations. First we deal with actual operations evaluation and proposed the bridge connection. In the next section we evaluate the operation of the bridge connection in the specific operating conditions. Finally, we evaluate the losses in the distribution network 110 kV. If the calculations of the stabilized operation or the short-circuit conditions of distribution network discovers that some of its elements are overloaded, we propose changes to ensure safe and reliable operation of the distribution network.

Interested in being notified about new results for this query?